Sector 74, Mohali, Punjab
1 Piece (MOQ)
Business Type | Manufacturer, Exporter, Supplier |
Type | Digital Water & Soil Analysis Kits |
Certification | ISO 9001:2015 & CE Certified |
Feature | Measures 8 parameters - pH, mV/ORP, Conductivity, Salinity, D.O., Temperature, TDS and Turbidity |
Click to view more |
Preferred Buyer From
Location | Worldwide |
Product Details
VSI Electronics Private Limited is one the leading manufacturers, suppliers and exporters of Water and Soil Testing Instruments in India. These Water and Soil Analysis kits are widely used for field testing of important parameters such as pH, ORP, Conductivity, TDS, Salinity, Dissolve Oxygen, Turbidity, Colorimeter and Temperature. VSI Electronics Private Limited’s instruments are used for efficient use of nutrients in the soil, to test the purity of drinking water and for waste water testing etc. These water and soil analysis kits are available in portable briefcase making them very convenient for field measurements.
Microprocessor based Water & Soil Analysis Kit (VSI-302) for the measurement of eight (8) parameters - pH, Conductivity, ORP, TDS, Salinity, D.O. , Turbidity & Temperature with 16X2 alpha numeric LCD display, Rechargeable Battery cum Mains operated with all accessories fitted in a briefcase. Data storage facility up to 1000 samples and external printer attachment facility available.
SALIENT FEATURES
We also offer many other models of Water & Soil Analyzer Kits.
Digital Water and Soil Analysis Kit (VSI-06) for the measurement of (6) parameters - O.R.P., pH, Temperature, Conductivity, Dissolved Oxygen, and Total Dissolved Solids (TDS) complete with combination pH Electrode, Temperature Probe, Cond./TDS Cell, D.O. Probe, D.O. Membranes, buffer solutions and manual. 3½ digit LCD display, Battery/Mains operated, fitted in a briefcase.
Digital Water and Soil Analysis Kit (VSI-06D) for the measurement of (4) parameters - O.R.P., pH, Temperature and Conductivity complete with combination pH Electrode, Temperature Probe, Conductivity Cell, buffer solutions and manual. 3½ digit LCD display, Battery/Mains operated, fitted in a briefcase.
Digital Water and Soil Analysis Kit (VSI-6D1) for the measurement of (4) parameters - pH, Conductivity, Total Dissolved Solids (TDS) and Temperature complete with combination pH Electrode, Conductivity/TDS Cell, Temperature Probe, buffer solutions and manual. 3½ digit LCD display, Battery/Mains operated, fitted in a briefcase.
Digital Water and Soil Analysis Kit (VSI-06T) for the measurement of (6) parameters - pH, Conductivity, TDS, Turbidity, Dissolved Oxygen, and Temperature complete with combination pH Electrode, Cond./TDS Cell, Test Tubes, D.O. Probe, D.O. Membranes, Temperature Probe, buffer solutions and manual. 3½ digit LCD display, Battery/Mains operated, fitted in a briefcase.
Digital Water and Soil Analysis Kit (VSI-07) for the measurement of (7) parameters - O.R.P., pH, Temperature, Conductivity, Dissolved Oxygen, Total Dissolved Solids (TDS) and Salinity complete with combination pH Electrode, Temperature Probe, Cond./TDS/Salinity Cell, D.O. Probe, D.O. Membranes, buffer solutions and manual. 3½ digit LCD display, Battery/Mains operated, fitted in a briefcase.
Digital Water and Soil Analysis Kit (VSI-07C) for the measurement of (9) parameters - pH, mV, Conductivity, Turbidity, Colorimeter, TDS, Salinity, D.O & Temperature complete with combination pH Electrode, Temperature Probe, Cond./TDS/Salinity Cell, D.O. Probe, D.O. Membranes, buffer solutions, Test Tubes for Turbidity, Test Tubes for Colorimeter and manual. 3½ digit LCD display, Battery/Mains operated, fitted in a briefcase.
Microprocessor based Water and Soil Analysis Kit (VSI-301) for the measurement of seven (7) parameters - pH, Conductivity, ORP, TDS, Salinity, D.O. & Temperature with 16X2 alpha numeric LCD display, Battery cum Mains operated with all accessories fitted in a briefcase. Data storage facility up to 1000 samples and external printer attachment facility available.
Note : Appearance & Specifications are subject to change due to continuous development.
Technical Specification of Digital Water & Soil Analysis Kit
pH MEASUREMENT Range : 0-14 pH Resolution : 0.01pH Accuracy : ± 0.01 pH ( relative) Temp. Compensation : Automatic with Pt-100 Probe & Manual By Keys Buffer Recognition : 4.00, 7.00 & 9.20 ( Automatic) Calibration : Automatic & Manual : 2 Point, 3 Point (Programmable) |
DISSOLVED OXYGEN MEASUREMENT Range : 0 to 20 ppm Resolution : 0. 1 ppm Calibration : Automatic Accuracy : ± 0.2 ppm ± 1digit Temp. Compensation : Automatic with Pt-100 Probe & Manual By Keys Pressure Comp. : 0-999 mm of Hg ( Manual) Salinity Correction : 0-20 mg/l |
mV/ORP MEASUREMENT Range : - 1999 to +1999 mV Resolution : 1 mV Accuracy : ± 0.1% ± 1digit Calibration : Manual |
TEMPERATURE MEASUREMENT Range : -20.0 to +200 degree C Resolution : 0.1 degree C Accuracy : ± 0.2% ± 1digit Input : Pt-100 Calibration : Manual |
CONDUCTIVITY MEASUREMENT Range : 0-1000 mS/cm Range Selection : Automatic Resolution : 0.01/ 0.1/ 1 uS/cm or mS/cm as per range No. of Ranges : Six Accuracy : ± 0.5% Temp. Compensation : Automatic with Pt-100 Probe Ref. Temperature : 25oC/20 degree C (Programmable) Temp. Co-efficient : 0-4% adjustable Cell Constant : 0.05 to 2.0 adjustable |
TDS MEASUREMENT Range : 0-200ppt in 5-Ranges Automatic Resolution : 0.01/0.1/1 ppm or ppt as per Range Temp. Comp. : Automatic Accuracy : ± 0.5% TDS Factor : 0.50 By Default (Adjustable) Cell Constant : 0.05 to 2.0 Adjustable Ref. Temperature : 25oC/20 degree C (Programmable) |
SALINITY MEASUREMENT Range : 0-200ppt in 5-Ranges - Automatic Resolution : 0.01/0.1/1 ppm or ppt as per Range Temp. Compensation: Automatic Accuracy : ± 0.5% Salinity Factor : 0.75 By Default( Adjustable) Cell Constant : 0.05 to 2.0 Adjustable Ref. Temperature : 25oC/20 degree C (Programmable) |
TURBIDITY MEASUREMENT Range : 0-1000 NTU in Two Ranges Resolution : 0.1 NTU in Lowest Range Range Selection : Automatic Accuracy : ± 3% FS ± 1 digit Detector : Photodiode/Photocell Sample System : 30 mm Clear Glass Test Tubes Light Source : 6V Tungsten Lamp Calibration : Manual |
DATA INTERFACE RS232 & Parallel output available for interfacing to computer/printer. STANDARD ACCESSORIES 1. Combined pH electrode 2. Buffer solutions 3. Conductivity/TDS/Salinity Cell 4. Temp. probe 5. DO probe, DO membranes, KCL 6. Operation manual 7. Test Tubes 8. Data Cable ADDITIONAL ACCESSORIES ON REQUEST 1. ORP Electrode AT AN EXTRA COST 2. Soil Probe AT AN EXTRA COST |
GENERAL SPECIFICATIONS Display : 16 Characters X 2 Lines Alpha Numeric BL LCD Display Format : Temp. and Parameter Simultaneously Real Time Display: 24 Hour Mode With Date & Time Controls : By Soft Keys Menu Driven Memory Storage : Up to 1000 samples Power Supply : 230 V ± 10%, 50 Hz AC & In-built Rechargeable Battery Digital Output : Serial RS-232 : Parallel Centronics Print Format : All Data / Date Wise (Programmable) Error Indication : pH Error, ORP Error, T-Error |
Hi! Simply click below and type your query.